EMB 7300 10A & 20A

Reference number:

EMB7300 10A 1 SHEV & 1 vent group : 683010-0101
EMB7300 10A 1 SHEV & 2 vent groups : 683010-0102
EMB7300 10A 2 SHEV & 4 vent groups : 683010-0204

EMB7300 20A 1 SHEV & 2 Vent groups : 683220-0102
EMB7300 20A 2 SHEV & 4 Vent groups : 683220-0204

 

 

Mention the desired references

##

Fulle Control – everytime

Both smoke and heat exhaust ventilation or natural ventilation: our control units offer the best solution for your electric window opening.

EMB7300 – Feature / Equipment

  • CD with free of charge software “EMBKompakt” for configuration of basic functions
  • Further settings (e. g. maintanance period) – only available with fee required software license
  • Plug-in module slots for signal monitoring and transduction (emergency open, fault)
  • Network port for connection and integration in building management systems (LON, KNX)
  • Connection input for wind and rain sensors
  • Various operating and display elements
  • Cable entry from above, below or behind of the housing
  • Additional housing for flash mounting
  • Prepared for connection of backup batteries (72 hours)
  • Further options on request

EMB7300 – Highlights

  • Control panel compliant with prEN 12101-9
  • Power supply compliant with EN 12101-10
  • 2 detector line groups with line monitoring to connect:
    •  Manual break glass units (HSE)
    •  Automatic smoke and heat detectors
  • 1 ventilation line input (optionally 2) with OPEN-STOP-CLOSE function
  • 2 Plug-in module slots for signal monitoring and transduction
  • Network port for connection and integration in building management systems (LON, KNX)
  • 1 connection input for wind and rain sensors
  • Various operating and display elements
  • Various setting options of basic functions via “EMB compact” software
  • Special functions programmable via fee required software as in the following:
    •  Service and maintanance interval
    •  Changes of priorities, switching-threshold or of their monitoring
    •  Control of the alarm functions by a volt-free contact of the fire alarm system
    •  Network integration
  • Housing (optional) with integrated break-glass unit and ventilation button
  • Lead frame usable for flash mounting
  • Cable entry from above, below, or behind the housing
  • Prepared for connection of backup batteries (72 hours)

Mounting

AUMÜLLER control units EMB7300 can be used in SHEV systems as well as for natural ventilation via automated windows.

The EMB7300 versions with 2,5 and 5 A are to be installed either surface mounted or flash mounted. These versions are available with a pre-mounted break glass unit on the housing cover.

Control units with an output current of 10 A or 20 A are suitable for surface mounting as well as for flash mounting. The cable entry from above, below or behind the housing is possible in all control units without any problem.

Natural  SHEV saves lives

DOWNLOADS